VRA Screen is a digital VRA device. As with VRA201, you present the sound with the audiometer. But instead of animating a toy, you present the visual reward via 1-3 screens, depending on your setup.
Processor: Intel Core i7 or AMD Ryzen 7 (or higher)
Graphics Card: NVIDIA GeForce RTX 30 series or AMD Radeon RX 6000 series
"The PA5 is a portable audiometer primarily used for conducting hearing tests in various environments. Its purpose is to assess individuals' hearing abilities quickly and accurately, making it valuable in clinical settings, schools, workplaces, and other locations where hearing screenings are necessary."
Portable Design: Compact and lightweight for easy transportation.
"The AD226 is designed for routine air and bone conduction threshold audiometry. With an extended license, it can also perform additional advanced hearing tests by adding them to the test battery.“
Specification:
Storage space for 500 patients
Portable: option to run on AA batteries
Lightweight with optional carrying bag
Weight: 1.3 kg / 2.9 lbs
Compact footprint: 30x23x9 cm, 12x9x4 inches
Portability: Excellent due to its lightweight design
Office space suitability: Ideal for limited office space due to its compact size
"The AD528 is a diagnostic audiometer, capable of performing essential tests like air conduction, bone conduction, and speech audiometry. Its compact design and user-friendly interface make it ideal for clinics, hospitals, or fitting shops.“
Specification:
Starts in a few seconds
Easy to use
Fast masking on/off
5" display
CD, MP3, live voice, and built-in speech materials.
"The AD629 is a hybrid diagnostic audiometer, offering the flexibility to use it either as a standalone device or as a PC-based system, depending on your preference.“
Specification:
Full PC-integration (true hybrid)
Extensive diagnostic test battery
Large 5,7’’ adjustable high resolution graphical color display
Internal storage for 500 patients/50,000 test sessions
Integrated pre-recorded speech
Multiple user settings (protocols)
Direct print options
Compact and portable design (35 x 29 cm / 14 x 11 inch.)
"The AC40 sets a new standard in clinical audiometry with its advanced features. It offers a wide range of tests with dedicated screen layouts for each assessment. Its user-friendly interface and customizable parameters cater to individual patient needs. With robust data management and seamless integration, it optimizes workflow efficiency. Portable and adaptable, it fits seamlessly into diverse clinical settings, representing the pinnacle of modern audiometric technology.“
Specification:
Full clinical test battery with dedicated screen layouts.
Pre-programmed, user-defined, or automated test sequences.
The Luna screening audiometer offers a solution for conducting quick and dependable screening audiometry. Its efficient design enables swift assessments, ensuring timely results for patients. With Luna, healthcare professionals can streamline their screening processes, providing accurate evaluations with ease and confidence.
Specification:
The headset audiometer only weighs 500 grams including the patient response.
Randomized frequency order for reliable results and no bulky equipment to manage.
Test at scale with automated tests and plug-and-play functionality
The term "Audiometer Keyboard" suggests a specialized keyboard designed for audiometry testing purposes. This keyboard likely includes dedicated keys or buttons that allow audiologists or clinicians to control the audiometer during testing sessions.
The Viot™ from Interacoustics is the natural choice for clinics that need an easy-to-use video otoscope for preliminary diagnostic assessments. Viot™ objectively views the external auditory canal before, during and after any audiological procedure.
Specification:
Ergonomic design for comfort and ease.
Auto white balancing for instant use.
Single-button control for full ear assessment.
90˚ angle view for simultaneous observation.
Compatible with Viot™, Affinity2.0/Equinox2.0, Callisto™ Suites, and Windows®10.
Fully integrates with Noah and OtoAccesss™ databases.
Callisto™ provides a range of diagnostic capabilities, covering different aspects of hearing assessment and fitting of hearing instruments. This includes audiometry to measure hearing thresholds, real-ear measurement to assess the performance of hearing aids in real-world situations, visible speech mapping for fine-tuning hearing aid settings, and hearing instrument testing to ensure optimal functionality.
Specification:
Adept as a portable audiometer
PC-based testing
No need for a power supply - connect to a USB port
All-in-one - from audiometry to fitting of hearing devices
AA222 is a combined tympanometer and audiometer. The combination of tympanometry and audiometry in one device offers all the diagnostic tests needed in your clinic.
The senti desktop flex offers an affordable, adaptable solution for audiometry needs, boasting portability and battery operation. Its user-friendly color touch screen ensures effortless navigation. With calibration data stored on the transducer, swapping becomes hassle-free, eliminating recalibration needs.
Audiometric Tests
:
Pure-Tone Audiometry with bone and air conduction, talk through, masking, free field and much more.
Play audiometry MAGIC: Multiple-Choice Auditory Graphical Interactive Check
Speech tests in multiple languages
:
SUN: Speech understanding in Noise screening test
UST: Universal Speech Test adaptable to different languages
MATCH: Mainzer audiometric test for children - image based speech test for children
from 2-5 years.
MAUS: screening test for auditory perception and processing orders for children from 6-
11 years
.
Piccolo stands as a portable, computer-driven audiometer, featuring air, bone, and speech audiometry capabilities. Its sleek, lightweight design, coupled with robust, user-friendly software and seamless Noah connectivity, positions Piccolo as the ultimate selection for professionals who are always on the go.
MODELS
:
Basic: only PTA – AC
Plus: only PTA – AC / BC
Speech: PTA & Speech – AC / BC
AVAILABLE SIGNALS
:
Stimulus: pure tone, warble tone
Masking: NBN, WN, SN (Piccolo Speech only)
Only Piccolo Speech:2 external inputs for speech audiometry
MIC input for live speech audiometry
SIGNAL SPECIFICATION
:
Attenuator step: 1 dB, 3 dB, 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz)
Triangle, a portable screening audiometer powered by batteries, conducts automatic and manual pure tone audiometry tests in air conduction and can also be optionally licensed for bone conduction exams. It's the perfect solution for mobile professionals
VAILABLE SIGNALS
:
Stimulus: pure tone, warble tone
Masking (optional, with “Bone Connectivity” license): NBN, WN
SIGNALS SPECIFICATION
:
Attenuator step: 5 dB
Presentation: Continuous, Pulsed (1 and 2 Hz)
Warble: 5 Hz sine wave modulating signal
AVAILABLE OUTPUTS AND TRANSDUCERS
:
AC: DD45 or DD65 headphones, ER-3C insert earphones
BC: B71 bone vibrator
AVAILABLE TESTS
:
Manual Pure Tone audiometry
Automatic Pure Tone audiometry (available algorithms: HughsonWestlake, Quick Search, Fixed Intensity)
Bell, an audiometer designed for screening and diagnosis, excels in swiftly and precisely conducting air and bone threshold tests. With its straightforward operation, user-friendly interface, and effortless portability, Bell stands as the perfect tool for private clinics, multi-specialist clinics, and occupational medicine settings.
AVAILABLE SIGNALS
:
Stimulus: pure tone, warble tone
Masking: NBN, WN
SIGNALS SPECIFICATION
:
Attenuator step: 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz)
Harp an advanced audiometer for fast, accurate exams in air, bone, and speech. Its top features, user-friendliness, and portability make it the ideal choice for diverse users.
AVAILABLE SIGNALS
:
Stimulus: pure tone, warble tone
2 external inputs for speech audiometry
MIC input for live speech audiometry
Internal input (flash memory) for speech audiometry
(Harp Plus only) Masking: NBN, WN, SN
SIGNALS SPECIFICATION
:
Attenuator step: 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz)
Cello, a computer-controlled audiometer, provides fast, accurate exams for air, bone, and speech audiometry, with added tests like QuickSIN™ and HF audiometry, prioritizing comfort and precision.
AVAILABLE SIGNALS
:
Stimulus: pure tone, warble tone
2 external inputs and USB audio for speech audiometry
MIC input for live speech audiometry
Masking: NBN, WN, SN
SIGNALS SPECIFICATION
:
Attenuator step: 1, 2 and 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz)
Warble: 5 Hz sin wave modulating signal
AVAILABLE OUTPUTS AND TRANSDUCERS
:
AC: Headphones (TDH-39 / DD45)
HF headphones (HDA-300 / DD450)
Insert earphones (ER-3 / IP30)
BC: B-71 bone vibrator
Free field Insert masking earphone: IME-100
AVAILABLE TESTS
:
Full audiometric evaluation: pure tone, auto thresholding, and high-frequency audiometry
Advanced clinical audiometer with dual independent channels and intuitive touch screen display for seamless test management. Its premium features, flexibility, and user-friendly design make it the top pick for clinics and hospitals.
AVAILABLE SIGNALS
:
Stimulus: pure tone, warble ton
2 external inputs for speech audiometry
MIC input for live speech audiometry
Internal input (flash memory) for speech
audiometry
Masking: NBN, WN, SN
SIGNALS SPECIFICATION
:
Attenuator step: 1, and 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz or custom freq.),
Single Pulse (with selectable
duration)
Warble: 5 Hz sin wave modulating signal.
AVAILABLE OUTPUTS AND TRANSDUCERS
:
AC: TDH-39 or DD45 headphones, ER-3 or IP30 insert earphones,
HDA-300 / DD450 headphones (Piano Plus / Plus VRA only)
BC: B-71 bone vibrator
Free field
Insert masking earphone: IME-100
AVAILABLE TESTS
:
Pure Tone audiometry
Auto threshold (modified Hughsone-Westlake)
Speech audiometry (2 channels)
ABLB
MLB
SISI: automatic score; 1 dB increment (5 dB for familiarization)
DLI, with increments between 0 and 5 dB
Tone decay, with 60 or 120 sec. duration
Stenger, with pure tone or speech stimulation
2 independent channels Master Hearing Aid
TEN test
QuickSIN test (optional)
CALIBRATION
:
Validity: 12 months
All the parameters set through the device software
Visual Reinforcement Audiometry (VRA) is a crucial hearing behavioral assessment designed for infants and toddlers experiencing hearing impairment. It plays a pivotal role in concluding the diagnostic journey for infants identified with hearing loss through newborn screening. VRA, alongside CPA tests, can be conducted using two Inventis audiometers: Piano Plus VRA and Cello (with VRA license activated).
Discover MAICO's EasyTone audiometer, offering precise audiometric testing capabilities in a user-friendly design. Experience seamless screening and diagnostic assessments with advanced features tailored for clinical settings. Elevate your hearing healthcare practice with the efficiency and reliability of MAICO's EasyTone audiometer
Features at a Glance:
:
State of the art tablet audiometer
Audiometer built-in easyTone headphone
Overall pass/refer result
Easy transition from screening to threshold determination
Guided workflow preventing operator errors and saving time
Discover the MA 1 audiometer from MAICO Diagnostics, offering precise hearing evaluation capabilities. Engineered with advanced technology for accurate screening and diagnosis. Explore its features for comprehensive audiometric testing.
Discover the MA 25 audiometer by MAICO, designed for comprehensive hearing assessment. With its intuitive interface and precise testing capabilities, the MA 25 ensures accurate results. Explore advanced features tailored for screening, diagnosis, and clinical applications.
Features at a Glance:
:
Air conduction audiometer
11 frequencies from 125 Hz to 8000 Hz
Test signals from -10 dB HL to 100 dB HL
Pure tone and warble tone (pulsed or continuous)
Portable and lightweight, only 980 g
Use with 3 AA batteries, power supply or USB cable to PC
MA 25e version including automated Hughson-Westlake test, talk forward and MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Discover the MA 27 audiometer by MAICO Diagnostics, a versatile tool for precise hearing assessments. With its intuitive interface and comprehensive features, the MA 27 ensures accurate screening and diagnostic evaluations. Experience efficiency and reliability in audiometric testing with the MA 27
Features at a Glance:
:
Air conduction audiometer
11 frequencies from 125 Hz to 8000 Hz
Test signals from -10 dB HL to 100 dB HL
Pure tone and warble tone (pulsed or continuous)
Compact and portable with built-in handle
Integrated compartment for storing accessories
MA 27e version including automated Hughson-Westlake test, talk forward and MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Explore the precision of audiological evaluation with MAICO's MA-28 audiometer. From screening to diagnostic assessments, experience versatile testing capabilities. Designed for clinical efficiency, the MA-28 delivers reliable results for comprehensive hearing evaluations
Features at a Glance:
:
Air conduction audiometry
Optional bone conduction audiometry
Compact and portable with integrated handle and compartment
The MA 33 audiometer by MAICO Diagnostics offers precise screening capabilities with its comprehensive features. Designed for efficiency and accuracy, it simplifies audiometric testing procedures. Experience reliable results and enhanced patient care with the MA 33 audiometer
Features at a Glance:
:
Air Conduction and Bone Conduction
Pilot-Hearing test for children
SISI, Stenger and automatic Hughson-Westlake tests available
Intuitive handling of the clearly presented user interface
Operate at your convenience with your mouse or keyboard
The MA42 audiometer from MAICO Diagnostics offers comprehensive testing capabilities for accurate assessments of hearing thresholds. With its intuitive interface and advanced features, the MA42 ensures efficient and precise audiometric evaluations. Designed for versatility and reliability, the MA42 is a trusted tool for audiologists and healthcare professionals worldwide
Features at a Glance:
:
Air, bone and speech 2 channel audiometer
Mixing signals and channels independently
Connection of one or two AC transducers, BC and sound field testing
Optional high frequency audiometry up to 16,000 Hz
Advanced diagnostic test functions
Included Special Tests: Pure Tone Stenger, Speech Stenger, MHA
Optional Extended Special Tests: SISI, Tone Decay, ABLB, MLB, Langenbeck test
Full colorful display with simple screen design
Small footprint for ease of portability
Easy access to talk forward, talk back and monitor functions
Direct printout of the results, store report as PDF or quickly transfer to MAICO Sessions PC software
Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
The PILOT TEST audiometer presents a playful approach to children's hearing screenings. Tailored for providers who recognize the need for customized solutions, it acknowledges that there's no universal solution for screening children's hearing
Features at a Glance:
:
More than just an auditory test: Hearing – Understanding – Implementing
2-in-1 screening device: pure tone audiometry and select picture audiometry
Pilot Hearing Test is available in different languages
Colorful child-friendly device
Full frequency range for pure tone testing (125 to 8 kHz)
Maximize efficiency and savings in your hearing conservation program with the TREMETRICS RA660, capable of testing up to eight individuals simultaneously. Simplify the process with the TREMETRICS HearCon Software, offering both manual and automatic testing options for a comfortable and intuitive experience
Features at a Glance:
Quickly test up to 8 people at the same time
Intuitive testing with TREMETRICS HearCon Software
Optional room monitor for analyzing ambient noise
Talk-over communication to any or all test subjects
Portable and lightweight at 500 grams
Automatic voice-instructions in multiple languages
Automatic or manual testing with customizable settings
Bio-Acoustic Simulator for daily calibration and checks
Tailor your Titan to suit your screening, diagnostic, and advanced clinical testing requirements. Align the modules with your present needs, and seamlessly upgrade as your challenges evolve. The Titan offers Impedance, ABRIS, OAE, and the groundbreaking Wideband Tympanometry functionalities.
Features at a Glance:
Optional high frequency probe tones(678, 800 and 1000Hz)
High resolution color display
Powerful 3D image of tympanometric data across a full range of frequency and pressure.
DP range 0.5-6 kHz
TE range 1-4.5 kHz (60-84 dB SPL)
Features Impedance, ABRIS, OAE, and Wideband Tympanometry.
Utilizes "Endless Airflow" pressure control technology.
The AT235 represents an automated middle ear analyzer designed to cater to diagnostic and clinical assessments with ease. It boasts additional features such as pure tone audiometry and the Modified Hughson Westlake audiometry test, making it a comprehensive tool for auditory evaluation.
Features at a Glance:
+400 to -600 daPa
High resolution color display
Direct printing to PC printers
User-defined protocols
HDMI output
Child distraction function
Internal memory that can store up to 500 clients and 50,000.
The MT10 is excellently tailored for diagnostic purposes, meticulously capturing tympanograms and offering optional reflex response recordings with remarkable detail. With the MT10, you can identify conditions like otitis media, perforated eardrums, cholesteatomas, and specific neurological disorders.
The Clarinet serves as a clinical middle ear analyzer, equipped with all necessary tests for a precise investigation of disorders. This includes automatic and manual tympanometry, acoustic reflex threshold, decay, and latency examinations, as well as ETF for both intact and perforated eardrums, and high-frequency and multi-component tympanometry.
PROBE TONE :
Frequency: 226 Hz, 678, 800, 1000 Hz (Clarinet Plus only)
Level: 85 dB SPL (@ 226 Hz), 80 dB SPL (@ 678 Hz), 75 dB SPL (@ 800, 1000 Hz)
ADMITTANCE MEASUREMENT SYSTEM
:
Measurement range:
-2.0 to 8.0 mmho (@ 226 Hz)
-4.0 to 16.0 mmho (@ 678, 800 and 1000 Hz)
AVAILABLE TESTS
:
Tympanometry (automatic and manual)
Multi-component tympanometry (Plus only)
Acoustic Reflex Threshold (automatic and manual)
Acoustic Reflex Decay
Acoustic Reflex Latency
Eustachian Tube Function (intact and perforated TM)
Flute functions as a diagnostic middle ear analyzer, conducting swift and reliable automatic sequences of tympanometry and reflex threshold tests. Moreover, it conducts manual reflex and reflex decay tests, ETF tests, and high-frequency tympanometry with exceptional precision and efficiency.
PROBE TONE :
Frequency: 226 Hz; 1000 Hz (Flute Plus w/optional license and Flute HF)
Level: 85 dB SPL (@ 226 Hz); 75 dB SPL (@ 1000 Hz)
VOLUME RANGE
:
0.2 to 8.0 ml (at 226 Hz)
0.9 to 16 mmho (at 1000 Hz) (Plus and HF)
PRESSURE SYSTEM
:
Rotary type pump with endless flow
Manual pressure adjustment available in the tympanometry and reflex tests (Flute Plus only)
AVAILABLE TESTS
:
Tympanometry (automatic)
Acoustic Reflex Threshold (automatic)
2 Automatic test sequences (tympanometry + reflex test)
Only Flute Plus
Tympanometry (manual)
Acoustic Reflex Threshold (manual)
Acoustic Reflex Decay
Eustachian Tube Function (intact TM)
Only Flute HF
Eustachian Tube Function (intact and perforated TM)
ACOUSTIC REFLEX DECAY TEST
Ipsilateral and contralateral stimulation
Non-acoustic stimulation (Flute Plus only)
Stimulus ON-Time: selectable from 0.5s to 2.5s
Stimulus OFF-Time: selectable from 0.5s to 2.5s
Four different tests available:
Automatic threshold
Fixed intensity
Growing intensity
Manual mode (Flute Plus only)
Viola is a combination unit that merges a screening middle ear analyzer, providing ultrafast and dependable tympanometry and reflex tests, with a diagnostic audiometer capable of conducting threshold and speech examinations in both air conduction (AC) and bone conduction (BC).
AUDIOMETER SPECIFICATIONS AVAILABLE SIGNALS
Stimulus: pure tone, warble tone
Masking: NBN, WN, SN
Only Viola Plus:
2 external inputs for speech audiometry
MIC input for live speech audiometry
Internal input (flash memory) for speech audiometry
SIGNALS SPECIFICATION
:
Attenuator step: 5 dB
Presentation: Continuous, Pulsed (0.5, 1 and 2 Hz)
Timpani, a portable tympanometry, provides automatic tympanometry and ipsi lateral acoustic reflex tests, along with screening for pure tone audiometry. Its rapid pressure pump system and specialized output for headphones distinguish Timpani as the sole handheld unit capable of conducting precise and thorough examinations.
AUDIOMETER SPECIFICATIONS
AVAILABLE OUTPUTS AND TRANSDUCERS
AC: supra-aural DD45, insert earphones ER-3C
AVAILABLE STIMULI AND LEVELS
:
Stimulus: pure tone (see table)
Attenuator step: 5 dB
Intensity: -10 to 100 dB HL
Frequency range: 125-8000 Hz
DEVICE SPECIFICATIONS
: PRINTER
Optional integrated Bluetooth thermal printer
Paper dimensions: 58mm
CALIBRATION
:
Validity: 12 months
All the parameters set through dedicated software.
COMPUTER INTERFACE
:
Connection: USB (driverless)
Compatible software: Inventis Maestro
DISPLAY
:
Type: Graphical color TFT LCD, capacitive touchscreen
The SENTIERO DESKTOP diagnostic unit offers Class 1 Tympanometry, Ipsi/Contra reflexes, ETF, and Multi-Frequency testing. Additional features include FMDPOAE pressurized OAEs and the option to add OAE, Pure Tone, and Speech audiometry modules.
DPOAE :
Minimum DPOAE level criterion: L1 – 70 dB and 4096 samples
Stimulus levels L2: 30 to 65 dB SPL; step size: 5 dB
TEOAE
:
Stimulation nonlinear protocol , level 85 db and
Sample rate: 48 kHz
Additional features
:
Optional Database Software (MIRA) - Data Management
test results to patient records with many EMR systems
The nanoTymp efficiently diagnoses middle ear problems across all age groups, boasting a simple test process and seamless USB connectivity. With real-time ear previews and rapid, colorful printouts, it stands out among screening tympanometers.
Upgrade your Diagnostic or Screening toolkit with the SENTIERO ADVANCED Tympanometry Add-On module. It's a plug & play solution that fits in your hand, offering quick Tympanometry tests in seconds. Whether for Screening or Diagnostic purposes, this versatile module seamlessly enhances your testing capabilities.
The easyTymp Pro combines the simplicity of a handheld screening tool with the precision of a diagnostic device, offering reflex decay and Eustachian Tube Function (ETF) testing alongside standard features
Enhance your tympanometry screenings with our touchTymp solutions, MI 24 and MI 26, featuring a user-friendly interface on a spacious 10.4” touchscreen for effortless parameter adjustments and streamlined workflow
Our diagnostic touchTymp versions offer intuitive ease of use, akin to the screening versions, while also providing additional diagnostic features for a comprehensive middle ear evaluation.
Reflex Decay test (ipsilateral and contralateral)ETF test for intact and perforated eardrumstouchTymp MI 36 includes AC & BC audiometryBuilt-in printer
Optional MAICO Sessions PC software connectable with OtoAccess® or Noah patient database for easy data management
The touchTymp RaceCar streamlines immittance testing by engaging children with an animated car race during tympanometry or reflex screening, making the process quick and enjoyable.
OtoRead™ merges swift and thorough testing of distortion product OAE (DPOAE) and transient evoked OAE (TEOAE) for newborns, children, and adults within a user-friendly, handheld device.
2 fixed DPOAE protocols
2-5 kHz
3 out of 4 for a pass
Test time of 2 or 4 seconds per frequency
The diagnostic version of the OtoRead™ gives you the option to also test up to 12 kHz.
The Sera™ device offers a powerful combination of hearing tests, including ABRIS, DPOAE, and TEOAE, ensuring early detection of hearing loss in newborns. Its intuitive interface and large touchscreen make it user-friendly and efficient for any screening program.
A versatile device offering auditory evoked potentials (AEP), auditory steady state response (ASSR), vestibular evoked myogenic potentials (VEMP) and otoacoustic emissions (OAE). Designed to fit seamlessly into your workflow and offers complete reliability and perfect results.
Solid and noise immune hardware
Modular platform
Unique pre-amplifier technology ensures optimum performance in electrically hostile environments
Intuitive interfaces, well-designed layouts, freedom to customize settings
QSCREEN caters to essential needs in newborn hearing screening with efficiency, accuracy, and reliability. It integrates TEOAE & DPOAE and unique features like FMDPOAE and multi-frequency testing. Its high-performance screening ABR is customizable to regional protocols, and its noise cancellation OAE probe enables testing in noisy environments, reducing test time by up to 20 times.
The SENTIERO screener, suitable for all ages, employs rapid two-frequency simultaneous DPOAE testing. With the option to integrate a built-in Pure Tone Screening audiometer, it ensures reliable results. Backed by over 20 years of PATH MEDICAL experience, it offers outstanding test performance. Simple and efficient to operate, it's ideal for screening across all age groups.
DPOAE
:
narrow band noise around 2f2-f1
Frequency ratio f2/f1: 1.22.
Minimum DPOAE level criterion: L1 – 70 dB
Safety standards - EN 60645-1 class 4
TEOAE
:
low Noise detection upto 85 dB peSPL
Stimulation nonlinear protocol , level 85 db and Sample
Otoacoustic emissions (OAE) are faint sounds produced in the inner ear in response to external sound stimuli. They exist in two forms: spontaneous (SOAEs) and evoked (EOAEs).
The ERO•SCAN provides simple frequency-specific TEOAE and/or DPOAE assessment, featuring user-friendly operation. Its clear organic LED display showcases line and bar graphs, facilitating straightforward evaluation
Features at a glance:
Screening and diagnostic measurements with TEOAE and/or DPOAE
Fast automatic OAE screening with Pass/Refer results and graphical displays
2 DP and 2 TE protocols for screening devices, 5 DP and 3 TE protocols for diagnostic devices
High noise immunity for operation in normal clinical environment
Our easyScreen combines ABR, TEOAE, and DPOAE screening functions into a single device, offering a cost-effective two-step ABR/OAE Hearing Screener solution tailored to your requirements
Features at a glance:
Fast and accurate ABR + OAE Hearing Screening
Powerful automated ABR Screening method with CE-Chirp® stimulus
Intuitive user interface and large colour touchscreen
Pocketsized and lightweight
Optional HearSIM™ patient database and device manager
Optional easyCart for an organized mobile workplace
The easyScreen combines ABR, TEOAE, and DPOAE screening functions into a single device, offering a cost-effective solution for a two-step ABR/OAE Hearing Screener
Features at a glance:
Fast and accurate ABR + OAE Hearing Screening
Powerful automated ABR Screening method with CE-Chirp® stimulus
Intuitive user interface and large colour touchscreen
Pocketsized and lightweight
Optional HearSIM™ patient database and device manager
Optional easyCart for an organized mobile workspace
The MB 11 BERAphone® revolutionizes Newborn Hearing Screening with its patented Auditory Brainstem Response system, providing a rapid automated ABR test for newborns, eliminating the need for adhesive disposables
Features at a glance:
Fast and automated ABR-screening, reliable results within seconds
Eco-friendly BERAphone® with reusable electrodes
Automatic skin impedance check ensuring precise and clear signal conditions
Cutting-edge PC software for easy operation
Guided screening process with on-screen instructions
The MB 11 Classic provides quick, automated Auditory Brainstem Response screenings for newborns, integrating measurement control, result viewing, and patient data management into one streamlined software solution
Features at a glance:
Fast and automated ABR Screening with CE-Chirp® stimulus
Simultaneous binaural screening
Automatic skin impedance check ensuring precise and clear signal conditions
Guided screening process with on-screen instructions
The SENTIERO screener is designed to conduct rapid two-frequency simultaneous DPOAE testing for individuals of all ages, starting from newborns. It also offers the option to include a built-in Pure Tone Screening audiometer. With over 20 years of PATH MEDICAL experience behind its development, the SENTIERO screener ensures outstanding test performance. Whether testing infants or adults, this screener delivers reliable results with straightforward and efficient operation.
Specifications:
Probe Performance Check: Assess sound pressure, speaker symmetry, and probe fit for accuracy.
Calibration: Perform in-ear calibration with volume adjustment for precision.
Noise Detection and Rejection: Identify narrow-band noise, use weighted averaging for noise calculation, and reject artifacts.
Employ 1.22 f2/f1 ratio at 48 kHz with L1 – 70 dB criterion and 4096-sample interval. Utilize diverse stimulus modes for multi-channel DPOAE, auto frequency adjustment (1-8 kHz), and default SNR stop criteria for efficient testing.
Additional feature:
Simultaneous measurement on left/right ear with 2 probes
Entertainment mode for all OAE modules
Optional Database Software for easy data management and result export
Noah compatible, facilitating interoperability with EMR systems
Technical Specifications:
Device dimensions: 209 x 98 x 52 mm, 500 g, with a 240 x 320 pixel 3.5” touch screen, real-time clock, sound generator, and USB.
Output voltage and nominal impedance: 5 Vpp, 32 Ω at the headphone socket.
Power consumption: Maximum of 2 W.
Memory capacity: Up to 1000 patients and approximately 1000 tests (dependent on test type).